BPTLW - FIBERGLASS FABRIC (TEFLON COATED FIBERGLASS

  • MSDS: BPTLW
  • Manufacturer: J P STEVENS AND CO INC
  • Product Name: FIBERGLASS FABRIC (TEFLON COATED FIBERGLASS
  • National Stock Number: 9340-00N033819
Product Identification

Product ID:FIBERGLASS FABRIC (TEFLON COATED FIBERGLASS
MSDS Date:06/22/1987
FSC:9340
NIIN:00N033819
MSDS Number: BPTLW

Responsible Party
J P STEVENS & CO INC
33 STEVENS STREET
GREENVILLE, SC 29602
US

Emergency Phone: 803-239-4129

Info Phone: 803-239-4129

Cage: IO369

Contractor
J. P. STEVENS & CO., STEVENS INDUSTRIAL DIV.
GREENVILLE, SC 29602 US

Telephone: 803-239-4129

Cage: 4X691

Ingredients

FIBROUS GLASS; (FIBROUS GLASS DUST)

CAS: 65997-17-3

OSHA PEL 15 MG/M3 (MFR)

ACGIH TLV: 10 MG/M3


NONE.

RTECS: 9999999ZZ


(TEFLON)R COATING-NO DISCERNABLE ODOR.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:OSHA CLASSIFIED FIBROUS GLASS AS
NUISANCE DUST. ACUTE: INHAL: MECH IRRIT OF MOUTH, NOSE,& THROAT.
SKIN: TRANSIENT MECH IRRIT. EYE: DIRECT CONT WILL CAUSE MECH IRRIT.
INGEST: UNLIKELY TO OCCUR. CHRONIC : INHAL: MANY STUDIES HAVE BEEN
CONDUCTED TO DETERM LONG TERM EFTS OF FIBROUS GLASS INHAL.ALTHOUGH
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: INCONCLUSIVE, SOME RESEARCH INDICATED
MFG EMPLOYEES FIRST EMPLOYED MORE THAN 30 YRS AGO IN FACTORIES THAT
MFR GLASS WOOL & MINERAL WOOL HAVE AN INCR RATE OF LUNG CANCER AS
COMPARED TO CERTAI N OTHER REFERENCE POPULATIONS. FURTHER STUDY IS
PLANNED TO IDENTIFY THOSE FACTORS ASSOC W/REPORTED INCR RATE.
(SUPDAT)
Medical Cond Aggravated by Exposure:ANY CONDITION GENERALLY AGGRAVATED
BY MECHANICAL IRRITANTS IN AIR OR ON SKIN.

First Aid

First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. GET MEDICAL
ASSISTANCE IF IRRITATION PERSISTS. SKIN: WASH WITH SOAP AND WATER.
INHALATION: REMOVE TO FRESH AIR. DRINK WATER TO CLEAR THROAT AND
BLOW NOSE TO EVACUATE FIBERS. INGEST: OBSERVE INDIVIDUAL. IF
SYMPTOMS OF GI IRRITATION DEVELOP, CONSULT PHYSICIAN.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . THERMAL DECOMPOSITION OF FIBER COATING MAY
PRODUCE AN IRRITATING MIX OF SMOKE & FUMES.
Unusual Fire/Explosion Hazard:IN EXTREME FIRE SITUATIONS INVOLVING
TEFLON, HYDROGEN FLUORIDE FUMES CAN BE LIBERATED AND APPROPRIATE
PERSONAL PROTECTIVE GEAR SHOULD BE EMPLOYED.

Accidental Release

Spill Release Procedures:PREVENT THE SPREAD OF FIBERGLASS DUST & AVOID
DUST GENERATION CONDITIONS. THOSE INVOLVED IN CLEAN UP OF
PARTICULATES SHOULD USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.
VACUUM CLEAN DUSTS. IF SWEEPI NG IS NECESSARY, USE DUST
SUPPRESSANT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AND USE IN A MANNER THAT WILL
PREVENT AIRBORNE PARTICULATES IN WORKPLACE.
Other Precautions:NONE KNOWN.

Exposure Controls

Respiratory Protection:WHERE DUST LEVELS EXCEED TLV, USE NIOSH/MSHA
APPROVED RESPIRATOR TO PROTECT AGAINST NUISANCE DUSTS.
Ventilation:LOC EXHST RECOM FOR PROCESSING MACHINARY WHERE DUST
GENERATION IS APPARENT. MECH WHERE LOC EXHST VENT IS NOT FEASIBLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WORK APRONS OR SMOCKS ARE RECOMMENDED. WEAR
LOOSE FITTING,LONG SLEEVED CLOTHING. BARRIER CREAMS.
Work Hygienic Practices:WASH THOROUGHLY AFTER WORK. RECOMMEND LAUNDER
WORK CLOTHES SEPARATELY AND WIPE OUT WASHER AT END OF CYCLE.
Supplemental Safety and Health
EFTS OF OVEREXP: SIMILAR FINDINGS WERE NOT REPORTED REGARDING EMPLOYEES
IN TEXTILE FIBER MFR PLANTS. ANIMAL STUDIES HAVE NOT DEMONSTRATED
AN INCR RATE OF LUNG CANCER WHEN ANIMALS BRTH LRG QTYS OF GLAS S
FIBERS.ARTF IMPLANTATION OR INJECTIONOF FINE GLASS FIBERS INTO
CHEST, ABDOMINAL CAVITY/TRACHEA OF LAB ANIMALS (ING 2)

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:1292F,700C
Spec Gravity:2.5 (H*2O=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:WOVEN FABRIC COMPOSED OF FIBERGLASS YARN
W/POLYTETRAFLUOROETHYLENE (ING 3)

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:HYDROGEN FLUORIDE.

Disposal

Waste Disposal Methods:IN MOST CASES, WOVEN FIBERGLASS SCRAP CAN BE
DISPOSED OF IN A SANITARY LANDFILL IN ACCORDANCE WITH FEDERAL,
STATE, & LOCAL REGULATIONS. CHECK WITH LOCAL AUTHORITIES ON ANY
QUESTIONS CONCERNING DISPOSA L.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.